Home > Products > Register Your Interest in Upcoming Products > 3226 Trunk Port FXO Doorphone

3226 Trunk Port FXO Doorphone

3226 Trunk Port FXO Doorphone

Analog Trunk Port Doorphone for Visitor Entry with Integrated Door / Gate Control Relay – 24V

The 3226 analog trunk port doorphone is an analog intercom for hands-free visitor communication at a secure entrance door or gate. This analog intercom / doorphone is outdoor rated.

  • FXO analog trunk port interface to a telephone system or directly to an analog telephone.
  • Digital speech technology provides superior voice quality.
  • NEMA 3R outdoor rated.
  • Seamless relay activation via telephone keypad during the intercom call for secure door or gate entry.
  • Two-piece solution including controller + intercom secures the access control relay.
$765.00 USD
SKU: 3226 Category:

Description

The 3226 analog trunk port doorphone is UL/CSA and FCC certified. This doorphone kit includes a controller, intercom station with stainless steel faceplate, surface mount bracket for wall mounting and 24V power supply. The intercom station can also be flush mounted into a double gang box (not included). Mounting gaskets are also included in the kit for installing the intercom in any outdoor environment. A brass faceplate is available for separate purchase.

 

How the Algo Analog Trunk Port Doorphone Works

  • Visitors press the call button on the 3226 intercom station to initiate calling as an outside line appearance on a telephone system or direct calling to an an analog telephone (two-line preferred so intercom calls can be handled separately).
  • Answering the intercom call enables two-way communication with the visitor. Any telephone, device or client on the UC platform can communicate with the doorphone if integrated to a telephone system  (e.g., mobile or wireless phone, soft client on a tablet or laptop, desk phone).
  • Alternatively, the doorphone can be called directly from any telephone or device. The doorphone will auto-answer to permit a two-way voice call via the intercom station.
  • During the intercom call the telephone keypad can be used to enter a door open code (e.g. digit 6, or up to four digits). Once activated the doorphone access control relay will permit a momentary unlock of the entrance for the visitor to gain access through the door or gate in a secure and efficient manner. Note: Duration of the relay activation is configurable, as is the open code.

Secure Door / Gate Access Control

A controller + intercom station are two components of the 3226 doorphone kit. The controller provides the telephone connection and the relay for door / gate access control. As the controller is generally located inside the premise, the 3226 is a secure solution in the event there is tampering of the public-facing intercom station. The access control relay is in no way exposed, and unauthorized entry to the building is prevented.

The 3226 access control relay can connect to any type of industry standard door strike, gate activation system or access / security control panel. A 30V 1A normally open or normally closed relay is available from the controller for this purpose. A door strike is not included with the 3226 doorphone kit.

VIDEO: How To Wire A Door Strike

Generally it is best the strike power be provided using the manufacturer’s power supply, however, the 3226 doorphone can provide 24V DC strike power (current limited to 300mA). The power supply is earth grounded to meet safety and regulatory requirements when extending the doorphone outside the perimeter of the building to a gate.

Wiring an Algo 3226 Intercom

 

Auxiliary Low Voltage Inputs & Outputs

A number of low voltage programmable inputs and outputs available from the controller and intercom station. Common uses for the auxiliary relays include configuring an input to use an existing doorbell, for example, or a relay output to activate a loud ringer or strobe light for intercom call telephone ring alerting. A door sensor input is also available for configuration, including the option to activate an alarm if the door remains open for an extended period (e.g., tailgating, leaving the door ajar).

 

Legacy Analog Doorphone Retrofit

The 3226 is ideally suited as retrofit solution of an existing analog intercom. It is often the case that 24 gauge twisted pair wiring is used with legacy intercom systems. This wiring can be re-used to connect the 3226 controller to the Algo intercom station, thereby saving time and money in not having to re-wire. Twisted pair wiring can also be used to wire the relay for door / gate control. Note: The controller can only be wired to the Algo intercom station in the 3226 kit.

 

Benefits of the Algo Analog Trunk Port Doorphone

  • Seamless analog trunk port integration or direct connection to an analog telephone.
  • Digital speech technology provides superior voice quality.
  • Two piece solution including controller + intercom station secures the access control relay.
  • Twisted pair 24 gauge wiring simplifies retrofit applications when upgrading legacy analog intercom systems.
  • Extended wiring flexibility of up to 1000 feet (305m) for gate applications outside the perimeter of the building.
  • Backlit call button for better visibility in low light conditions.
  • Supervised link to intercom station monitors fault conditions to minimize down time.
  • Configurable through software via USB or by telephone keypad using touch-tone (DTMF) commands.
  • Ideal for door / gate entry, in addition to controlling access points to elevators, secure areas such as a day care, hospital ward, lab or data center.

Features

  • Digital speech technology provides superior voice quality.
  • Initiates or accepts intercom calls.
  • Supervised link to intercom station monitors fault conditions to minimize down time.
  • Integrated access control relay from separate controller located securely from the public-facing intercom station.
  • 24 gauge twisted pair wiring up to 1000 feet (305m).
  • Backlit call button for low light conditions, with button flash indication for call initiation and connectivity.
  • Surface mount or flush mount installation in standard double gang box.
  • Complete doorphone / intercom solution as one part number / SKU.
  • 24V power supply included. Earth grounded to meet safety and regulatory requirements for extending doorphone beyond a building perimeter to a gate.
  • UL/CSA and FCC certified; NEMA 3R outdoor rated.
  • Dimensions – Intercom Station: 4.5” x 4.5” x 1.2” (11.5 cm x 11.5 cm x 3.1 cm), Controller: 5.6″ x 6.9″ x 1.6″ (14.2cm x 17.5cm x 4.1cm)

Specifications

Power
Power Input: AC Mains Adapter 120V/230V Included
Typical (idle): 1.5 Watts
Maximum: 10.5 Watts (Audio active, door contacts using 24V, 0.3A auxiliary supply)
Telephone
Connect to FXS gateway or telephone system analog station port
Ring Voltage: 65 Vrms ring voltage 20 or 25 Hz Sinewave, REN=2
Talk Battery: 48V DC, 30 mA current limit
CLID: GR-30-CORE, BT 227, and ETS 300 659-1
Ring Cadence: Programmable
Ring Persistence: Programmable
Door Control
Contact Rating: Maximum 30V 1 Amp
Contact Type: 1 Form C; Normally Open and Normally Closed
Duration: Programmable, including latch
Activation: DTMF, programmable
Auxiliary Power: 24V DC, current limited to 300mA
Terminal Block Wiring: 12-26 AWG
Programming
Method: DTMF or USB Port using configuration software
Faceplate
304 Stainless Steel included; Brass faceplate available for separate purchase. Optional Vandal-Proof model (part no. 3203 for intercom station or as a doorphone kit part no. 3226V)
Input/Output
Controller Dry Contact Input: Contact detected using 24V DC, 1mA (programmable function) Maximum resistance 1 kΩ
Door Station Dry Contact Input: Contact detected using 24V DC, 1mA (programmable function) Maximum resistance 1 kΩ
Controller Dry Contact Output: Maximum 30V, 50mA switching (programmable function)
Door Station Dry Contact Output: Maximum 30V, 50mA switching (programmable function)
Door Station Call Button: Backlit tactile silicon rubber
Environmental & Mechanical
Doorstation rated for Outdoor Use CSA/UL NEMA 3R (appropriate gaskets may be required)
Operating temperature -30 to 60° C (-22 to 140 F)
Controller rated for indoor use 0 to + 40° C (32 to 104° F); 10-95% RH non-condensing
Dimensions (Door Station): 4.5” x 4.5” x 1.50” (11.5 cm x 11.5 cm x 3.8 cm)
Dimensions (Controller): 6.9” x 5.6” x 1.6” (17.4cm x 14.2cm x 4.0cm)
Weight (Door Station): 0.5 lbs (0.23 kg) / Weight (Controller): 1.0 lbs (0.45 kg) / Weight (Shipping): 3.1 lbs (1.41 kg)
Compliance
RoHS, CE, FCC, CSA/UL (USA & Canada), EN60950

Applications

  • Visitor communication and access control through secure door / gate entrances (e.g., school, long-term care / assisted living retirement facility, hotel / resort, casino, transport terminal (i.e., airport, bus, rail), delivery entrance, dock, warehouse, man trap, outdoor yard or facility entrance, parking lot, driveway gate, etc.).
  • Intercom for emergency (e.g., elevator) and non-emergency access points (e.g., student dorm, hospital ward, day care, conference room, recreation area, office suite, data center, lab, etc.).
  • Office or room intercom (e.g, medical examination or patient room, interview room, etc.).

 

 

Ordering Guide

ItemProduct Code
3226V Vandal-Proof Trunk Port (FXO) Doorphone3226V
3100 Surface Mount Conduit Box3100

Resources